Home Up Information FAQ's Search News

 wpe3.jpg (12582 bytes) -Hardware-  

          -mini model- -standard model-

Up
-Hardware-
-Software-
-Dealers-

Sentry data loggers

pcb_001.jpg (16024 bytes)

The basic of the data logger is a small intelligent Printed Circuit Board (PCB) with the size of a matchbox. Together with several interface PCB's, or direct integration of the logger PCB itself in sensors or devices,

we can create any logger you want.

With the Sentry data logger system you will get a standard in your organization    together with a flexible, universal and modular system to registrate any unit you would like.

Key Benefits

bulletSmall sized
bulletBattery powered
bullet12 bit resolution
bulletUp to more then 160.000 readings
bullet8 universal channels (incl. pulse)
bulletAlarm messages on GSM phones with SMS (Short Message Services).

Specifications Sentry data loggers:

Logger PCB:
Number of channels: Max. 8, 0..2,5 VDC unprotected, full scale  
Type of channels: Analog, digital or counter  
Memory: 128 kB or 512 kB  
Resolution: 12 bit - 0.025% full scale (1/4096)  
Accuracy 0.25%  
Size 57 x 45 x 16 mm  
Weight 50 gram  
Interface PCB:
Combination of:    
Analog channels: 0...100 mV, 5, 10, 20 V., 0...20 mA Temperature (NTC)  
Digital channels: Dry contact or voltage (0-0.6 Vdc low,, 2-3 Vdc high) Impedance: >>1MOhm
Counter channels (max. 1): Dry contact or voltage (0-0.6 VDC low,, 2-3 Vdc high) Impedance: >>1MOhm

Pulse period: min. 2 microSec.

Frequency: max. 25,000 Hz.

Accuracy: 10 msec. / interval

Collector output for: Battery powered sensors Only for standard model
  External alarm devices Only for standard model
  Battery powered GSM, Radio modems Only for standard model
Or special interfaces for: Temperature (PT-100, Thermo couple) Only for standard model
  Counter channels (max. 5): Only for standard model
Universal MODELS:
Mini Max. 4 external channels Size: 92 x 55 x 26 mm
Standard Max. 8 external channels

Alarm output options, special interfaces

Size: 120 x 80 x 60 mm
(see below excl. enclosure).
Recording information:    
Analog Scrolling average or mathematics average  
Digital Total time closed contacts during registration period

Enable or disable collecting data on all channels

Time of input change (event logging)

 
Counter Number of pulses in one registration period (Hz or Pulse/t)  
Stored measurement Absolute value calculated by 4 parameters  
Standard readings Each registration period 40,952 or 163,808 (512 kB)
Optional method Event logging 17,000 or 68,000 (512 kB)
Recording interval Sample period 1 Hz ... 250 days
  Registration period (average of samples) 1 Hz ... 250 days
Programmable limits 2 levels for min. and/or max. alarms Option to send SMS or alarm
Regular information:    
Environment conditions Temperature -20 to 70°C. (ambient)
  Relative Humidity 0 - 95% RH.
  International Protection IP50 (option IP65 standard model)
Internal clock Accuracy max. +/- 2 sec./day within temp. range System based on GMT (Greenwich Mean Time).
Battery life: 10 year, factory replaceable Lithium 1,5 Ah.-3,6 V. SL386
  Mini model 10 year, factory replaceable Lithium 2,3 Ah.-3,6 V. AA axial
  Standard model 5 year. Lithium 2,3 Ah.-3,6 V. AA
  There is no battery consumption during RS-232 communication  
Communication interface LEMO connector 5-wire or

DB9 female (option standard model)

Interface cable with connector or

DB9 cable (option standard model)

  RS-232 - 9600 baud  
 